반응형
Column Simulation 중에 Tray Rating을 했는데요. Koch Flexitray 를 사용했습니다.
아래 메세지는 왜 나온걸까요? 해결 방법은?
* WARNING
CORRELATION LIMIT(S) VIOLATED DURING KOCH TRAY RATING
CALCULATIONS. EXTRAPOLATION IS USED.
SET DIAGNOSTICS LEVEL TO 6 TO SEE DETAILS.
The message levels for convergence diagnostics are:
Level | Description |
0 | Only convergence block terminal error messages are listed. |
1 | Level 0 and convergence block severe error messages are listed. |
2 | Level 1 and convergence block error messages are listed. |
3 | Level 2 and convergence block warnings are listed. |
4 | Level 3 and brief diagnostic information are listed. |
5 | Level 4 and information on unconverged variables at each iteration are listed. |
6 | Level 4 and information on every variable at each iteration are listed. |
7-8 | Level 6 and additional diagnostics for analyzing convergence are listed. This varies for each convergence algorithm. |
반응형
'ASPEN Plus' 카테고리의 다른 글
Error message : Vapor or liquid flow on stage 1 is tending to disappear (0) | 2017.02.02 |
---|---|
60 Commonly Asked Petroleum Application Questions About Aspen Plus (0) | 2017.01.23 |